Step flashing and kick-out flashing code

Short answer

Where a shingle roof meets a sidewall, base flashing must be continuous or step flashing at least 4 inches high and 4 inches wide (IRC R905.2.8.3, 2021). A diverter (kick-out) flashing is required where the eave of a sloped roof meets a sidewall (IRC R903.2.1).

Sidewall flashing

  • Continuous or step flashing, at least 4 in. × 4 in., directing water onto the roof or into the gutter.
  • Where siding is present, the vertical leg runs continuously under the siding – which is why siding at the wall line often has to be detached and reset.
  • Older editions (2012/2015) say “step-flashing method”.

Kick-out flashing

IRC R903.2.1 requires flashing that diverts water away from where the eave of a sloped roof intersects a vertical sidewall. It is counted per location (EA).

Quantity

Sidewall length in LF from the measurement report; headwall (apron) flashing separately. Add siding or trim detach and reset only where photos show it is needed to install the flashing.

Codes are adopted by states, counties and cities, often with amendments. The edition and amendments adopted where the house stands are what count – section numbers here follow the 2021 IRC model code. This guide is general information, not legal advice.