Shingle nailing: 4 nails, 6 nails and the code

Short answer

The IRC requires at least four fasteners per strip shingle or two per individual shingle (R905.2.6), with corrosion-resistant roofing nails of at least 12 gauge shank and 3/8-inch head that penetrate the deck at least 3/4 inch or through it (R905.2.5). More nails apply where the manufacturer or the wind design requires them.

Fasteners

  • Galvanized steel, stainless steel, aluminum or copper roofing nails.
  • Minimum 12-gauge shank and 3/8-inch head.
  • Penetrate at least 3/4 inch into the deck or through the sheathing.

How many nails

  • Code minimum: 4 per strip shingle, 2 per individual shingle.
  • Many manufacturers call for 6 nails for high-wind application or enhanced wind warranties.
  • On slopes steeper than 21:12, follow the manufacturer’s steep-slope instructions.

Wind classification

Shingles must be classified for the design wind speed (R905.2.4.1, ASTM D7158 or D3161). The local design wind speed comes from the jurisdiction.

Codes are adopted by states, counties and cities, often with amendments. The edition and amendments adopted where the house stands are what count – section numbers here follow the 2021 IRC model code. This guide is general information, not legal advice.