Roof ventilation code: 1/150 and 1/300
Enclosed attics and rafter spaces need ventilation (IRC R806.1). The net free ventilating area is at least 1/150 of the vented space’s area, or 1/300 when the code’s conditions are met – for example with balanced high and low vents (R806.2).
The ratio
Attic floor area ÷ 150 = net free vent area (square feet). With the 1/300 exception, typically 40–50 % of the vent area in the upper part of the space (near the ridge) and the rest at the eaves, or a qualifying vapor retarder in the coldest climate zones.
In a replacement scope
Existing box vents, turbines, ridge vent and pipe jacks are replaced in kind when damaged or when removal is needed for the new roof. Count them from the report and photos. Changing the ventilation design is a design decision for the contractor, not something we add on our own.
Codes are adopted by states, counties and cities, often with amendments. The edition and amendments adopted where the house stands are what count – section numbers here follow the 2021 IRC model code. This guide is general information, not legal advice.